Having mini-split installation done is an excellent solution for solving comfort difficulties in your residence. These systems don’t require ductwork to give energy-efficient heating and cooling. Similar to any other home comfort system, they can experience issues occasionally. Here are seven of the most typical mini-split troubles and how you can resolve them.

1. Mini-Split Is Leaking or Struggling to Drain Water

If your mini-split is dripping water or not draining water, there could be a problem with the condensate drain or drain line. It’s typical for a drain line to become clogged with mold, forcing water to back up and drip. Call Kohles & Bach Heating & Cooling at 515-207-6569 for support and we’ll get your drain unplugged quickly.

2. Mini-Split Makes Constant Noise

Mini-splits normally don’t make much noise when they’re on. But there are two times where they might create sounds.

  • Popping or clicking: This can be because of the plastic housing expanding or contracting while the system is running.
  • Swooshing, crackling or gurgling: This can take place if your mini-split goes into defrost mode to prevent itself from freezing over.

You shouldn’t be alarmed if you hear these noises because they’re typical. However, if your mini-split keeps switching into defrost mode, it’s a symptom that something is wrong, such as low refrigerant, a faulty circuit board or defective sensors. Your Kohles & Bach Heating & Cooling HVAC technician will be able to find and correct the problem rapidly.

3. Mini-Split Isn’t Generating Heat

If your mini-split is not heating or blowing hot air, icy coils could be the problem. Like we mentioned prior to this, iced-over coils might be the consequence of low refrigerant, a failing circuit board or defective sensors. Call us at 515-207-6569 for assistance.

4. Mini-Split Is Not Cooling or Blowing Cold Air

If your mini-split is not cooling or blowing cold air, there may be a refrigerant leak. Your mini-split AC needs refrigerant to move heat and keep your residence cold. These leaks must be fixed by a licensed HVAC professional, so reach us at 515-207-6569 for support.

5. Mini-Split Drainage Is Clogged

Similar to an air conditioner, a mini-split is efficient at dehumidifying during the summer. However, this might be interrupted by mold in the condensate drain line. Another reason your mini-split air conditioner may not be dehumidifying very effectively is if it’s oversized. A system that’s oversized will cool down an area too rapidly without having a chance to dehumidify it. Mini-split size is planned on square footage and BTUs.

6. Mini-Split Smells

If your ductless mini-split smells, it’s trying to grab your attention that something is wrong. Here are five of the most common smells and what they mean.

Mold or Mildew

If your mini-split smells musty, sour or like mildew, you might have a mold issue. Have a professional like Kohles & Bach Heating & Cooling examine and rinse the condensate drain and drain line, if necessary.

Vinegar

If your mini-split smells like vinegar or has a sweet odor, you’re possibly encountering a refrigerant leak. Another surefire clue that you don’t have ample refrigerant is a low concentration of chilled air. Contact us at 515-207-6569 for assistance

Fish

If your mini-split smells like fish, a few things could be wrong. In some instances this smell means there are electrical issues or there’s a leak. Either way, contact us at 515-207-6569 for assistance.

7. Mini-Split Will Not Power On

If your mini-split will not power on, look at the remote first. If the batteries are bad, your mini-split won’t run. In most experiences, putting in new batteries will resolve the trouble. If you’re still running into trouble, call us at 515-207-6569.

Trust Us for All Mini-Split Repair Needs

When you need mini-split repair or air conditioning repair in Des Moines, get in touch with the company your neighbors and friends have relied on since {year}. Quality service, fair prices and your comfort are our top priorities! Call us at 515-207-6569 to request your appointment today.